Hoshizaki KM-1900SWH/3 Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
28
KM-1900SAH/3
KM-1900SRH/3
Bin Drain Outlet
3/4" FPT
Icemaker Water Supply Line Shut-Off Valve
Icemaker Water Supply Line Drain Valve
Icemaker Water Supply Inlet 1/2" FPT
Icemaker
Drain Outlet
3/4" FPT
Condensation
Drain Outlet
3/8" OD Hard
Tube
Bin
Icemaker
Remote Condenser Line Set Connections
Separate piping to approved drain.
Leave a 2 inch (5 cm) vertical air gap
between the end of each pipe and the
drain.
2-inch (5-cm)
air gap
Floor
Drain
Fig. 17
1. Icemaker
•Icemakerwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof3/8"nominal
ID copper water tubing or equivalent is required for the icemaker water supply line.
•Anicemakerwatersupplylineshut-offvalveanddrainvalveshouldbeinstalled.
•Icemakerdrainoutletis3/4"FPT.Aminimumof3/4"nominalIDhardpipeorequivalent
isrequiredfortheicemakerdrainline.Condensationdrainoutletis3/8"ODhardtube.
The condensation drain line can be connected to the icemaker drain line or can be run
separately.
Minimum 3/8" Nominal
ID Copper Water Tubing
Minimum 3/4"
Nominal ID Hard Pipe
Vent Tube
Vent Tube
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 37 38

Comentarios a estos manuales

Sin comentarios