107. Final Check List1) Is the icemaker level?2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F and the water te
1115) Has the safety switch been checked for correct operation? Activate the safety switch ontop of the spout. The ice machine should shut down immedi
129. Preparing the Icemaker for Long Storage- See Fig. 4WARNINGWhen shutting off the icemaker for an extended time, drain out all water fromthe water
13III. Cleaning and MaintenanceIMPORTANTEnsure all components, fasteners and thumbscrews are securely in place afterany maintenance or cleaning is don
148) Remove the thumbscrews attaching spout (A) to the evaporator assembly and lift offspout (A) and spout packing (A).9) Pour the cleaning solution o
15[d] Sanitizing Procedure - Initial1) Close the water supply line shut-off valve.2) In the storage bin, remove the thumbscrews attaching spout (B), t
166) Remove the thumbscrews attaching spout (A) to the evaporator assembly and lift offspout (A) and spout packing (A).7) Pour the sanitizing solution
172. MaintenanceIMPORTANT1. This icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemake
3) Air FilterA plastic mesh air filter removes dirt or dust from the air, and keeps the condenserfrom getting clogged. As the filter gets clogged, the
91A2HA10DHOSHIZAKIHOSHIZAKI AMERICA, INC.618 HIGHWAY 74 SOUTHPEACHTREE CITY, GA 30269U.S.A.PHONE: 770-487-2331www.hoshizakiamerica.com
2HOSHIZAKI AMERICA, INC.618 Highway 74 SouthPeachtree City, GA 30269Attn: HOSHIZAKI Technical Support DepartmentPhone: 1-800-233-1940 Technical Servic
3 • Please review this manual. It should be read carefully before the icemaker is installedand operated. Only qualified service technicians should i
4MODEL NUMBERSERIAL NUMBERAC SUPPLY VOLTAGECOMPRESSORGEAR MOTORFAN MOTOROTHERMAXIMUM FUSE USEMAX. HACR BREAKER (USA ONLY)MAX. CIRC. BREAKER (CANADA ON
52. Dimensions/ConnectionsF-500BAF, F-500BAF-CUnit = inches [mm.]
6II. Installation and Operating Instructions1. Checks Before InstallationWARNINGRemove shipping carton, tape(s) and packing. If packing material is le
73. LocationWARNINGThis icemaker is not intended for outdoor use. Normal operating ambienttemperature should be within +45°F to +100°F; Normal operati
85. Electrical ConnectionWARNING1. Electrical connection must be made in accordance with the instructions on a“WARNING” tag provided with the pig tail
96. Water Supply and Drain ConnectionsSee Fig. 3• External filters, strainers or softeners may be required depending on the waterquality.• Water suppl