Hoshizaki M029-897 Manual de usuario

Busca en linea o descarga Manual de usuario para Máquinas productoras de hielo Hoshizaki M029-897. Hoshizaki M029-897 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Hoshizaki

Hoshizaki “A Superior Degree of Reliability” www.hoshizaki.com ModelIM-500SAAStackable Square Cuber Hoshizaki America, Inc. SERVICE MANUALNumber: M02

Pagina 2

10ET temperature is recorded 30 seconds after PM energizes. Water temperature correction value (CB Setting 13) is added to ET temperature and this is

Pagina 3 - IMPORTANT

11C. Service Diagnosis TableFirst see "III.G. Error Codes." If there are no recorded errors, refer to the table below.No Ice Production - Po

Pagina 4 - Important Safety Information

12Low Ice Production - Possible CauseLong Harvest Cycle1. Evaporator a) Scaled up.2. Refrigerant Charge a) Low.3. Control Board a) Thermistor connecti

Pagina 5 - WARNING, continued

13Large-Hole Cubes - Possible Cause (Also see III.H.1. Dimple Diameter") 4. Icemaker Location a) Insufficient clearance.b) Ambient temperature to

Pagina 6 - A. Construction

14D. Bin Control Check and Cleaning1. Bin Control CheckThis appliance uses a lever-actuated proximity switch to control the ice level in the storage b

Pagina 7 - 1. Air-Cooled Model (SAA)

152. Bin Control CleaningScale may build up on BC. Scale can cause the actuator paddle and magnet to stick. In this case, BC should be cleaned. WARNIN

Pagina 8

16E. Evaporator Thermistor CheckTo check thermistor resistance, follow the steps below.1) Turn off the power supply. 2) Remove the front panel. Move t

Pagina 9 - B. Sequence of Operation

17III. Controls and AdjustmentsA. Control SwitchThe control switch has three positions: OFF for power off, ICE for icemaking, and WASH to energize the

Pagina 10

181. Control Board Layout• CN16 ConnectorActuator Motor Position Sensor (Hall IC) Input• CN11 ConnectorBin Control Input• CN13 ConnectorEvaporator (Cu

Pagina 11 - C. Service Diagnosis Table

19C. Control ButtonsThe control board features RESET, SERVICE 1, and SERVICE 2 Buttons1. RESET Button• Press briey to go to initial harvest cycle.• P

Pagina 12

2 WARNINGOnly qualied service technicians should install and service the appliance. To obtain the name and phone number of your local Hoshizaki Certi

Pagina 13

20D. Control Board SettingsNOTICEFailure to maintain factory settings may adversely affect performance and warranty coverage. For more information, co

Pagina 14

21Control Board (CB) Setting MenuCategory No. Item RangeIM-500SAA DefaultWater Supply, continued12Freeze Cycle Water Supply Time 1: Partial Drain (CB

Pagina 15 - WARNING

22Control Board (CB) Setting MenuCategory No. Item RangeIM-500SAA DefaultCompressor 37Compressor Output SelectionDO NOT ADJUST0: X8 (DC Relay) On1: X1

Pagina 16

23Control Board (CB) Setting MenuCategory No. Item RangeIM-500SAA DefaultWater Tank Ice Control & Harvest Cycle Low Temperature Control74Water Tan

Pagina 17 - B. Control Board

24Control Board Information DisplayNo. Item DescriptionHistory Cleared by Pressing and Holding SERVICE 1 and SERVICE 2 Buttons Simultaneously for 5Se

Pagina 18 - "IM" Control Board

25F. Control Board Model Code Setting1. Control Board Replacement WARNING• This appliance should be diagnosed and repaired only by qualied service pe

Pagina 19 - C. Control Buttons

265) Press the "SERVICE 1" button to increase the rst digit in the display and the "SERVICE2" button to increase the second digi

Pagina 20 - D. Control Board Settings

27G. Error CodesWhen the control board detects an error, the display shows one of the following error codes in the display mode. Error codes other tha

Pagina 21

28Error CodesError CodeProblem Corrective Action/Reset DetailsEE (E5)High Evaporator TemperatureIf evaporator temperature 140°F (60°C) or higher for 5

Pagina 22

293) Press the "SERVICE 2" button to lower freeze cycle termination temperature setting (Control Board Setting 2). Temperature setting lower

Pagina 23

3CONTENTSImportant Safety Information ... 4I. Constructi

Pagina 24

30IV. Refrigeration Circuit and Component Service Information WARNING• This appliance should be diagnosed and repaired only by qualied service person

Pagina 25

312. Brazing WARNING• R-404A itself is not ammable at atmospheric pressure and temperatures up to 176°F (80°C).• R-404A itself is not explosive or po

Pagina 26

325) Disconnect the gauge manifold hose from the vacuum pump and attach it to a refrigerant service cylinder. Remember to loosen the connection and pu

Pagina 27 - G. Error Codes

33Water Pan AssemblyRefer to illustration for assembly.Icemaking Assembly and Cam MechanismRefer to illustration for assembly.1. Water Tank2. Water Pl

Pagina 28 - H. Quick Adjustments

34V. MaintenanceThe maintenance schedule below is a guideline. More frequent maintenance may berequired depending on water quality, the appliance&apos

Pagina 29 - Water Tank Drain Pipe

35VI. Preparing the Icemaker for Periods of Non-UseNOTICE• When storing the appliance for an extended time or in sub-freezing temperatures, follow the

Pagina 30

36VII. DisposalThe appliance contains refrigerant and must be disposed of in accordance with applicable national, state, and local codes and regulatio

Pagina 31

37VIII. Technical InformationWe reserve the right to make changes in specications and design without prior notice.A. Specication Data1. IM-500SAAAC

Pagina 32

38B. Performance DataPressure data is recorded at 5 min. into freezing cycle. The data not in bold should be used for reference only.1. IM-500SA

Pagina 33

39C. Wiring Diagram1. IM-500SAA

Pagina 34 - V. Maintenance

4Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,

Pagina 35

5 WARNING, continued• The appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or

Pagina 36 - VII. Disposal

6I. Construction and Water/Refrigeration Circuit DiagramA. Construction1. Air-Cooled Model (SAA)Model Shown: IM-500SAAWater TankBin ControlEvaporator

Pagina 37 - A. Specication Data

7B. Water/Refrigeration Circuit Diagram1. Air-Cooled Model (SAA)Thermostatic Expansion ValveEvaporatorEvaporator ThermistorWater TankWater PumpCondens

Pagina 38 - B. Performance Data

8II. Sequence of Operation and Service DiagnosisA. Sequence of Operation Flow ChartLegend: AMD–actuator motor downAMU–actuator motor upBC–bin controlC

Pagina 39 - C. Wiring Diagram

9B. Sequence of Operation1. Startup CycleWhen power supply is turned on, "on" appears on CB display and HGV energizes. 30sec. later, harves

Comentarios a estos manuales