Hoshizaki KML-200MAE Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 51
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
5
* We reserve the right to make changes in specifications and design without prior notice.
I. SPECIFICATIONS
1. KML-200MAE
115/60/1
10.8 A (5 Min. Freeze AT 104° F / WT 80° F)
20A
20A
Ambient Water Temp. (°F)
Temp. (°F) 50 70 90
70 *250 (113)
240 (109) 220 (100)
80
241 (109)
226 (103) 210 ( 95)
90
230 (104) *214 ( 97) 199 ( 90)
100
218 (
99)
203 (
92) 187 ( 85)
Crescent Cube
3.9 lbs. (1.8 kg) 180 pcs.
N/A
90°F/70°F 70°F/50°F
820 (9.2) 760 (6.7)
64 (29.9) 81 (30.8)
30"x27-3/8"x22" (762x695x560 mm)
Stainless Steel, Galvanized Steel (Rear)
Net 150 lbs. (68 kg)
Permanent Connection
Inlet 1/2" FPT
Outlet 3/4" FPT
Float Switch
Hot gas and water, thermistor and timer
Timer controlled, Overflow pipe
N/A
Thermostat
Hermetic, Model RSU4-0050-CAA
Air-cooled, fin and tube type
Vertical type, Stainless Steel and Copper
Thermostatic Expansion Valve
R22, 1lb. (465g)
High 427 PSIG, Low 206 PSIG
High Voltage Cut-out (Internal)
Auto-reset Overload Protector (Internal)
Auto-reset High Pressure Control Switch
Float Switch
N/A
Ice Storage Bin
VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100°F
WATER SUPPLY TEMP. 45 - 90°F
WATER SUPPLY PRESS. 10 - 113PSIG
AC SUPPLY VOLTAGE
AMPERAGE
MINIMUM CIRCUIT AMPACITY
MAXIMUM FUSE SIZE
APPROX. ICE PRODUCTION
PER 24 HR.
lbs./day ( kg./day )
Reference without *marks
SHAPE OF ICE
ICE PRODUCTION PER CYCLE
APPROXIMATE STORAGE CAPACITY
ELECTRIC & WATER CONSUMPTION
ELECTRIC W ( KWH/100 lbs. )
WATER gal./24 HR. ( gal./100 lbs. )
EXTERIOR DIMENSIONS ( WxDxH )
EXTERIOR FINISH
WEIGHT
CONNECTIONS - ELECTRIC
- WATER SUPPLY
- DRAIN
CUBE CONTROL SYSTEM
HARVESTING CONTROL SYSTEM
ICE MAKING WATER CONTROL
COOLING WATER CONTROL
BIN CONTROL SYSTEM
COMPRESSOR
CONDENSER
EVAPORATOR
REFRIGERANT CONTROL
REFRIGERANT CHARGE
DESIGN PRESSURE
P.C. BOARD CIRCUIT PROTECTION
COMPRESSOR PROTECTION
REFRIGERANT CIRCUIT PROTECTION
LOW WATER PROTECTION
ACCESSORIES - SUPPLIED
- REQUIRED
OPERATION CONDITIONS
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 50 51

Comentarios a estos manuales

Sin comentarios